Complex Environment Test Equipment
• Use Environment regulation test of parts while developing products (Repeated test for the cycle of resistance of heat,
cold and humidity)
• Main Function Evaluate the test for the cycle of resistance of
humidity and heat, Check/evaluate the deformation
of single product and finished product
•Temperature Range : -30~150℃
•Humidity Range : 30~98%
endurance evaluation via constant temperature and constant humidity test as well as temperature and humidity cycle test
Multi Material Teat Equipment
• Use Physical property test for interior and exterior plastic parts
• Main Function Evaluate the physical property (Tensile, Elongation, Flexural , Flexural Elastic Modulus, Etc) of plastic partst
• Temperature Range -40℃~180℃
Pilot pressing-out Machine
• Use Develop materials (Test materials (Test materials production depending on materials and composition)
• Main Function Test production of interior and exterior plastic pats
Infrared Rays Spectrum Photometer(ATR)
• Use Quantitative and qualitative analysis of liquid, gas, solid
• Main Function Measure the purity of materials and the composition of compounds
Video-Microscope (KH-7700)
Surface analysis of chemical materials
Thermal shock tester
• Temperature Range -50℃~200℃
Endurance evaluation on cold energy